Metering pump -Adjusting the discharge of the metering pumps-

By turning the volume adjustment screw, the pumped volume per cycle can be changed.
Turning the volume adjustment screw clockwise (screwing the volume adjustment screw into the metering pump) decreases the pumped volume, and turning the volume adjustment screw anticlockwise (unscrewing the volume adjustment screw from the metering pump) increases the pumped volume. After making an adjustment, please tighten the volume adjustment screw with the locknut. The adjustable range of the pumped volume is limited by the number of turns, which is a few anticlockwise turns from the point where the screw is fully tightened (the pumped volume = 0mm3). Please see the table below.

 

Adjustable range of  pumped volume

 

Model number

Turns

MCP-50

2

MLP-200P

3

PKP-500P

4

 

 The list of metering pumps is here! 