Welcome to Takasago Electric, Inc., a leading manufacturer of valves, pumps and manifolds
Metering pump -The effect of operating frequency on repeatability-
A change in operating frequency affects pumped volume and repeatability. When the operating frequency is higher than the value specified on a drawing, repeatability decreases. An example of measured changes in repeatability resulting from varying operating frequencies is shown in the table below.
Model number used: NRP-500P
Measurement conditions:
The pumped volume is set at 500mm3 when the operating frequency is 2Hz.
(Other than the conditions specified below, the measurements follows the standard test conditions.)
Experimental data of repeatability versus operation frequency
|
Operating frequency |
Repeatability * |
|
5Hz |
+5.88% |
|
-7.00% | |
|
3.3HZ |
+5.08% |
|
-2.39% | |
|
2Hz |
+0.09% |
|
-0.28% | |
|
1.7Hz |
+0.09% |
|
-0.09% | |
|
1.3Hz |
+0.07% |
|
-0.09% | |
|
1Hz |
+0.10% |
|
-0.10% | |
|
Manual operation |
+0.12% |
|
-0.25% |
(* Upper row: error of the max. value, Lower row: error of the min. value)
TrackBack
Solenoid Valves >> Diaphragm Isolated Valves|Pinch Valves|Air Operated Valves|Shape Memory Alloy Valve
Miniature Pumps >> Micro Syringe Pumps|Piezoelectric Micro Pumps|Peristaltic Pumps|Metering Pumps
Manifolds and Chips >> Standard Manifolds|Customized Manifolds|Acrylic Manifold-mountable|Bonded PTFE manifold|Film Chips|Plastic Chips
Fittings2 >> Fittings for PTFE tubing